Dwyer UV Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Accessoires d'air Dwyer UV. Dwyer UV User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
12
[307.98]
15
[381.00]
17
[431.80]
1-7/16-18 UNEF
THREADS
1" MPT
THREADS
1-1/2
[38.10]
2-15/16
[74.51]
IN-LINE
THREADS
1" FPT
2-1/2
[63.50]
The Series UV In-Line Polysulfone Flowmeter measures
the flow of water, air, and other compatible media at tempera-
tures up to 212°F (100°C) and pressures up to 150 psi (10.34
bar). This flowmeter’s highly corrosion-resistant materials suit
it ideally for use with de-ionized water and ultra-pure applica-
tions, including food processing, medical equipment and
reverse osmosis water systems.
INSTALLATION
1. Select an indoor (only) location that is free from excess
vibration, within the specified temperature limits, and away
from direct sunlight. (Polysulfone is adversely affected by ultra-
violet light.)
2. Remove hollow plastic shipping tube from inside flow body.
3. Handle carefully. Hand-tighten aluminum ring.
O-Rings will seal if hand tightened only. Do not
overtighten the
adapters and fittings.
4. Install the flowmeter in an exact vertical plane, one that is in
proper alignment with the existing plumbing. Use wall or other
structural supports at the top and bottom of the unit. Do not
allow the instrument to support the weight of pipes or tubing.
5. Use pipe thread sealant tape. Do not
use pipe dope com-
pounds, which can craze and crack the polysulfone housing.
Hand tighten system pipe fitting to adaptor fitting. If additional
torque is needed to seal pipe joint, use strap wrench on adap-
tor fitting. Maximum torque is 22 Foot - Pounds.
6. If using solvent-based glues like PVC cement, in the piping
system, do so with the meter’s body removed until glue has
cured, then purge the system before re-installing. Do not sol-
der brass fittings with the body installed, because the heat
generated to solder the brass fittings will damage the flowme-
ter.
CAUTION: Ball valves and solenoid valves can have a “water
cannon” effect on opening, creating pressure that exceeds the
warrantied ratings and will damage the flowmeter.
SPECIFICATIONS
Service: Compatible liquids.
Wetted Materials: Polysulfone body, Fluoroelastomer O-Rings
and Virgin PTFE float.
Temperature Limits: 35 to 212°F (2 to 100°C); 35 to 130°F (2
to 54°C) for PVC Fitting Option.
Pressure Limit: 150 psi (10.34 bar).
Accuracy: ±2% Full Scale @ 70°F +/-2 F (21.1°C) and 14.7 psia
(In line connection rating only).
Repeatability: +/-1% full scale @ 70+/-2°F (21.1°C) and 14.7
psia (In line connection rating only).
Process Connections: 1˝ female NPT. Optional 90° Polysulfone
Elbow – 1˝ male NPT.
Scale Length: 6˝ (152.40) – 7˝ (177.80), depending on model.
Fitting Torque: Maximum 22 ft - lb.
Weight: 1 lb (457 g) (for 20 GPM range).
Series UV In-Line and Panel Mount Polysulfone Flowmeter
Specifications - Installation and Operating Instructions
Bulletin F-60
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
Optional
Polycarbonate
Shield
Teflon, Viton-Reg.TM E.I. du Pont de Nemours & Co.
Drawing at
right shown
with optional
Polysulfone
Fittings.
Picture at
left shown
with optional
Polysulfone
Fittings.
F-60:Series UV Bulletin 7/24/09 10:01 AM Page 1
Vue de la page 0
1 2

Résumé du contenu

Page 1 - DWYER INSTRUMENTS, INC

12[307.98]15[381.00]17[431.80]1-7/16-18 UNEFTHREADS1" MPTTHREADS1-1/2[38.10]2-15/16[74.51]IN-LINETHREADS1" FPT2-1/2[63.50]The Series UV In-L

Page 2

OPERATION AND MAINTENANCEOnce installed, the Series UV In-Line PolysulfoneFlowmeter is self-operating and requires no maintenanceother than an occasio

Commentaires sur ces manuels

Pas de commentaire