Series PVF and CPF Industrial Body PVC and CPVC FlowmetersSpecifications - Installation and Operating InstructionsBulletin F-23DWYER INSTRUMENTS, INC.
INSTALLATIONPREPARATION: Series PVF and CPF flowmeters are ready toinstall as-is, although the sight tube may need repositioning sothe scale is vis
Body Size and Description3/4˝ PVC-NPT connection1-1/2˝ PVC-NPT connection3˝ and 4˝ PVC-NPT connection3/4˝ PVC-Flange connection1-1/2˝ PVC-Flange conne
MaterialPVC/CPVCpfVARIES*dfVARIES** “Average” for these floats is f = 3.50, df = 217.8.EXAMPLE: Using a standard brass meter scaled for water (s =1.00
AVERAGE V.I.C., CENTISTROKES, FOR STANDARDSERIES PVF AND CPF FLOWMETERS100% GPM, SIZE 60.54 - 0.801.20 - 2.603.80 -7.0010.0 - 23.0CTS371525100% GPM, 1
REPLACEMENT PARTSUnder proper care, there should be no need to stockreplacement parts.Otherwise, parts only need to be replaced if damaged. Anyvisible
SYMPTOMFLOAT HANG-UPFLOAT BOUNCEAPPARENT FALSEREADINGS, GASMETERSAPPARENT FALSEREADINGS,LIQUID METERSUSUAL CAUSECaused by particles, sludge, etc. (inc
DWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.dwyer-inst.comP.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwye