Series BDL Button Data Logger
Specifications - Installation and Operating Instructions
Bulletin DA-USB
The Series BDL Button Data Logger records temperatures and humidi-
ty in applications where size and cost effectiveness are key. The BDL is housed
in a stainless steel case and is water resistant, making it durable in hostile
environments where excessive moisture is present. The BDL is self-powered
and features a USB interface. Sample rate and high/low alarms are user
selectable through the Windows
®
-based application. The included software
displays downloaded data graphically with trace and zoom functions. The
logger is very small which enables it to be inserted into small items and pack-
ages. The Series BDL-K Logger Kit includes 2 buttons, 2 magnets, an inter-
face cable, and a plastic button holder.
SOFTWARE INSTALLATION
1. Ensure that no applications are running.
2. Insert the installation CD and select the install option from the menu.
3. Follow the onscreen instructions.
4. Restart the computer. A new icon will be placed on the desktop.
5. After installing the software, connect the logger.
6. The first time you open the software, you will be prompted to enter a
password. The password will only be used if you decide to use the
security functions. Enter and take note of the password.
SOFTWARE FEATURES
• Graphing of downloaded data
• Zooming function
• Temperature in °F or °C
• Up to two traces per graph
• Multiple traces per graph (Full Version Only)*
• Exporting to spreadsheet (Full Version Only)*
• Viewing the data table (Full Version Only)*
• Calculating Mean Kinetic Temperature (MKT) (Full Version Only)*
• Emailing graphs (Full Version Only)*
*In order to obtain the Full Version Only features, the software upgrade key
must be purchased. To access the full version, the software key is inserted
into a USB port on the PC and the full version features are automatically
added onto the existing software.
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwyer-inst.com
SPECIFICATIONS
Range: BDL-1: -40 to 185°F (-40 to 85°C); BDL-2: -4 to 185°F (-20 to
85°C), 0 to 100% RH.
Memory Size: BDL-1: 2048 readings; BDL-2: 4096 temperature and
4096 humidity readings (Low Resolution), 2048 temperature and 2048
humidity readings (High Resolution).
Accuracy: BDL-1: ±1.5°F (±1°C) from -22 to 158°F (-30 to 70°C); BDL-
2: ±0.9°F (±0.5°C) from 14 to 158°F (-10 to 70°C), ±5% RH.
Resolution: BDL-1: 8 bit; BDL-2: 8 or 11 bit.
Sampling Method: Stop on memory full or continuous recording.
Sampling Rate: BDL-1: Selectable from 1 to 255 min; BDL-2:
Selectable from 1 sec to 24 hrs.
Computer Requirements: Windows
®
98, Windows
®
2000, Windows
®
ME, Windows NT
®
, Windows
®
XP, and Windows Vista
®
operating system
with 16 MB RAM, one free USB port.
Power Requirements: Internal, non-replaceable 3.0V lithium battery.
Battery Life: BDL-1: 10 years (approx); BDL-2: 5 years (approx).
Alarms: Programmable high/low.
Interface: USB port (cable included).
Housing Material: 305 stainless steel.
Weight: 0.14 oz (4g).
Agency Approvals: CE, RoHS.
Ø43/64
[Ø17.07]
1/4
[6.35]
Windows
®
, Windows NT
®
, and Windows Vista
®
are registered trademarks of Microsoft
Corporation.
DA-USB:TEMPLATE 9/22/08 9:35 AM Page 1
Vue de la page 0
1 2

Résumé du contenu

Page 1 - DWYER INSTRUMENTS, INC

Series BDL Button Data LoggerSpecifications - Installation and Operating InstructionsBulletin DA-USBThe Series BDL Button Data Logger records temperat

Page 2

DWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.dwyer-inst.comP.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. Fax: 219/872-9057 e-mail: info@dwye

Commentaires sur ces manuels

Pas de commentaire