December, 1998 Page 1 949-1190-1
INSTRUCTIONS FOR THE
2500 SERIES
MICROPROCESSOR BASED
TEMPERATURE CONTROL
Dwyer Instruments, Incorporated
PO Box 338 Michigan City, IN 46361-0338
(800) 828-4588 (219) 879-8000 FAX (219) 872-9057
www.love-controls.com
m
m
m
LOVE CONTROLS DIVISION
®
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1

December, 1998 Page 1 949-1190-1INSTRUCTIONS FOR THE2500 SERIES MICROPROCESSOR BASEDTEMPERATURE CONTROLDwyer Instruments, IncorporatedPO Box 338

Page 2

949-1190-1 Page 10 December, 1998compensate for sensor error. Note: InPC is reset to zero whenthe input type is changed, or when decimal position is

Page 3

December, 1998 Page 11 949-1190-1returns to the decimal point range, the display willautorange back to tenth dergee resolution.InPt Input Fault Timer:

Page 4 - Model 2 5

949-1190-1 Page 12 December, 1998ABSOLUTE ALARMSDEVIATION ALARMSALARM TYPE AND ACTION (if present)Caution: In any critical application where failure c

Page 5

December, 1998 Page 13 949-1190-1The following menu items apply only to the alarm.AL Alarms: Select OFF, Lo, Hi, or HiLo.OFF Alarms are turned OFF. No

Page 6

949-1190-1 Page 14 December, 1998SPECIFICATIONSSelectable Inputs: Thermocouple or RTD as ordered.Input Impedance:Thermocouple = 3 megohms minimum. RTD

Page 7

December, 1998 Page 15 949-1190-1DIAGNOSTIC ERROR MESSAGESACTION REQUIREDInput signals may normally go aboveor below range ends. If not, checkinput a

Page 8

949-1190-1 Page 16 December, 1998Input TypeRangeDIMENSIONSRTD TypesINPUT RANGESThermocouple TypesType J or L-100 to +1600-73 to +8711°F1°CType N-100 t

Page 9 - OFF, 0.1 to 99.9%. Select

949-1190-1 Page 2 December, 1998TABLE OF CONTENTSMODEL IDENTIFICATION... 4INSTALLAT

Page 10

December, 1998 Page 3 949-1190-1GETTING STARTED1. Install the control as described on page 4.2. Wire your control following the instructions on page 4

Page 11

949-1190-1 Page 4 December, 1998INSTALLATIONMount the instrument in a location that will not be subject to excessivetemperature, shock, or vibration.

Page 12 - ABSOLUTE ALARMS

December, 1998 Page 5 949-1190-1WIRINGDo not run thermocouple or other input wiring in the same conduit aspower leads. Use only the type of thermocou

Page 13

949-1190-1 Page 6 December, 1998°°FRONT PANEL KEY FUNCTIONSSet Point Lamp Alarm LampTemperature Display °F Indicator°C IndicatorSet Point DisplayDecim

Page 14

December, 1998 Page 7 949-1190-1While in the Primary or Secondary menu, if no key is pressed for aperiod of 30 seconds, the display will return to the

Page 15 - DIAGNOSTIC ERROR MESSAGES

949-1190-1 Page 8 December, 1998MENU SELECTIONSPRIMARY MENUPress INDEX to advance to the next menu item. Press UP ARROW orDOWN ARROW to change the v

Page 16 - LOVE CONTROLS DIVISION

December, 1998 Page 9 949-1190-1outputs. Set the value for the amount of temperature differencebetween the turn off point (set point) and the turn on