Operating instructions
Digital handheld
pressure gauge
HM28
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Digital handheld

Operating instructionsDigital handheldpressure gaugeHM28

Page 2 - Contents

10setrecint_30m * 235 CR (tab)ok * 13 CRsetrecint_60m * 238 (tab)oksetautooff_man * 198 CR (tab)ok * 13 CR Select autom. switching off time (minutes)s

Page 3 - Operating instructions

11Linearity, hysteresis andrepeatability(10 °C to 35 °C) ± 0,2 % F.S.(50 °F to 95 °F) (standard) ± 1 digit± 0,1 % F.S.(option) ± 1 digit± 0,05 % F.S.(

Page 4 - Î negative pressure

12 4.3 Power supply unit connectionThe HM28 can be operated by a regulatedplug-in power supply unit.Input 115V, 60 HzOutput 9 V DC ± 20 %, 100 mA(7 to

Page 5

13 7 AccessoriesStandard 1 9 V block battery1 operating instructionsOption Plug-in power supply unit115V, 60HzLeather case with carrying strapService

Page 6 - Î on the display appears

14 8 Calibration instructionsRecalibration to be carried out byspecially skilled staff only!Actuate the following key combinations:• First press MODE

Page 8 - ±4°C (±39 °F)

LOVE CONTROLS DivisionDwyer Instruments, Inc.Highway 212 AT 12Michigan City, IN 46360USAPhone ++1 219 879 8868Fax ++1 219 872 9057I-HM28/0501, Art. Nr

Page 9

2 Contents 1 Description...4 2 Safety details ...4 3 Operating ...

Page 10 - 4 Specifications

3ON = OnOFF = OffMODE = Select operating mode- Pressure measurement- Min./Max.- Leak rate- DataloggingCLEAR/ZERO = Zero settingPRINT/HOLD = Print and

Page 11

4 1 DescriptionThe „LOVE CONTROLS“ handheld pressuregauge HM28 is a digital pressure measuringinstrument with integrated pressure sensorfor the measur

Page 12 - 5 Maintenance

5Switching onNormal(differential)andanalogue/holdNormal(absolute)and differentialZoomMin/MaxLeak rateTendency(absolute)Record 1)Print Recordprinthol

Page 13 - 7 Accessories

6set unit mbar, kPa, bar, 2)mmH2O, mH2O,mmHg, psi, inH2O,inHg, hPa, Pa, MPaset highresolution1) lowset damping offonset baudrate 9600, 4800, 2400

Page 14 - 8 Calibration instructions

7Code ConfigurationPressure unitPressure unitPressure unitPressure unitPressure unit5 MPa(7-70bar)6 Pa(25mbar-7bar)7 kPa8 bar9 mH2O(with 70bar,otherwi

Page 15

8remote * 182 CR (tab)[ok] * 13 CR Switch to remote control andblock keypadlocal * 53 CR (tab)[ok] * 13 CR Switch to keypadoff * 101 CR (tab)[ok] * 13

Page 16

9setunit_mmh2o * 57setunit_mmhg * 255setunit_psi * 162setunit_inh2o * 54setunit_inhg * 252setunit_hpa * 143setunit_pa * 39setunit_mpa * 148setbaud_960